Detcon SG1 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Sensores Detcon SG1. Detcon SG1 User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 16
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
June 7, 2011• Document #3734 • Revision 0.0
Model SG1
Portable Single Gas Detector
Operator’s Instruction Manual
Covers O
2
, CO, H
2
S, H
2
and SO
2
Models
DETCON, Inc.
3200 Research Forest Dr.,
The Woodlands, Texas 77387
Ph.281.367.4100 / Fax 281.298.2868
www.detcon.com
Vista de página 0
1 2 3 4 5 6 ... 15 16

Resumo do Conteúdo

Página 1 - Model SG1

June 7, 2011• Document #3734 • Revision 0.0Model SG1Portable Single Gas DetectorOperator’s Instruction ManualCovers O2, CO, H2S, H2and SO2ModelsDETCON

Página 2 - Warranty and Repair

9Gas Concentration Values for Calibration of Single GasGasOxygenCarbonMonoxideHydrogenSulfideHydrogenSulfurDioxideConcentration0% 100ppm 50ppm 500ppm

Página 3 - Table of Contents

When the 1st alarm occurs, the operator can acknowledge it by pressing the Power key. Onlythe alarm sound stops. The LED will stay on until the readin

Página 4 - Product Specification

11While in the alarm 1 SET screen, press the Arrow key to select alarm 2. The icon will bedisplayed and blink. Set alarm 2 using the same method for a

Página 5 - LCD display symbols

12Applicable BatteryCaution: It is absolutely prohibited to replace battery in potential explosion areas ordangerous regions. Specification of the app

Página 6 - Start of Operation

13Battery & Sensor ReplacementWhen you replace the Battery and sensors of the SG1 unit,you need some tools and componentsas indicated below.- Tool

Página 7 - Operation Method

14Operational Flow Chart

Página 8 - Calibration

15Notice for UserPlease use the unit in ranges of applicable temperature, humidity and pressurethat are appropriate for the specification of the produ

Página 9 - Single Gas Calibration

1Warranty and RepairDetcon Inc. warrants the Model SG1 series to be free from defects in workmanshipof material under normal use and service for two y

Página 10 - Alarm Display

2Table of ContentsProduct Specification ------------------------------------------------3Names and Functions of Exterior -----------------------------

Página 11 - Alarm Set

3Product SpecificationModel SG1-O2 SG1-CO SG1-H2S SG1-H2 SG1-SO2O2CO H2S H2SO2Measured Gas0~30%0~500ppm0~1,000ppm0~100ppm0~200ppm0~20ppm0~100ppm0~20pp

Página 12 - Hold 3 secs

4Names and Functions of ExteriorLCD display symbols563421785. Backlight/Arrow Key6. Alarm LED7. Fastening Clip8. Type Label1. Gas Sensor2. Buzzer3. LC

Página 13 - External Pump (Optional)

5Start of OperationInstrument Power-OnPress Power key for 2 seconds to turn power on. (Power will not beturned on if the Power key is released before

Página 14 - Disassembly

6Operation MethodDetection ModeThe unit enters Gas Detection Mode when the power is turned on.Gas Detection Mode displays the concentration of the gas

Página 15 - Operational Flow Chart

7CalibrationCaution: Detcon Inc. performs the initial calibration prior to shipment. An incorrectlycalibrated value can reduce the accuracy of the pro

Página 16 - Parts List

8Caution: Fresh Air Calibration should be performed in an environment of fresh air without anyinfluence of other gases. The calibration is performed o

Comentários a estes Manuais

Sem comentários